Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 2.18PSI ~ 16.68PSI (15kPa ~ 115kPa), Output: Analog Voltage, Accuracy: 0.2 V ~ 4.7 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.87PSI (6kPa), Output: Analog Voltage, Accuracy: 0.3 V ~ 4.6 V,
Pressure Type: Board Mount, Operating Pressure: Vacuum, Output Type: -7.25PSI (-50kPa), Output: Analog Voltage, Accuracy: 0.06 V ~ 2.82 V, Voltage - Supply: ±2.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 2.9PSI ~ 16.68PSI (20kPa ~ 115kPa), Output: Analog Voltage, Accuracy: 0.399 V ~ 4.645 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 2.9PSI ~ 36.26PSI (20kPa ~ 250kPa), Output: Analog Voltage, Accuracy: 0.3 V ~ 4.9 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 7.25PSI (50kPa), Output: Analog Voltage, Accuracy: 0.2 V ~ 4.7 V,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Analog Voltage, Accuracy: 0.2 V ~ 4.7 V,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.57PSI (3.92kPa), Output: Analog Voltage, Accuracy: 1 V ~ 4.9 V, Voltage - Supply: ±6.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 7.25PSI (50kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (10V), Voltage - Supply: -0.6% ~ 0.4%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 7.25PSI (50kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (10V), Voltage - Supply: ±0.3%,
Pressure Type: Board Mount, Operating Pressure: Vacuum, Output Type: -16.68PSI (-115kPa), Output: Analog Voltage, Accuracy: 0.2 V ~ 4.6 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Analog Voltage, Accuracy: 0.1 V ~ 3.1 V, Voltage - Supply: ±5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 2.9PSI ~ 44.09PSI (20kPa ~ 304kPa), Output: Analog Voltage, Accuracy: 0.3 V ~ 4.9 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 5.8PSI (40kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 3.006 mV (6V), Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.87PSI (6kPa), Output: Analog Voltage, Accuracy: 0.2 V ~ 4.7 V, Voltage - Supply: ±5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 14.5PSI (100kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (10V),
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.57PSI (3.92kPa), Output: Analog Voltage, Accuracy: 0.6 V ~ 3 V, Voltage - Supply: ±2.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1.45PSI (10kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 65 mV (3V), Voltage - Supply: ±10%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 7.25PSI (50kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (10V),
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 29.01PSI (200kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (10V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 7.25PSI (50kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (10V),
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 7.25PSI (50kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (10V), Voltage - Supply: -0.6% ~ 0.4%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.57PSI (3.92kPa), Output: Analog Voltage, Accuracy: 1 V ~ 4.9 V,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1.45PSI (10kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 25 mV (10V),