Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±2%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 250PSI (1723.69kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 110 mV (5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 85 mV ~ 225 mV, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.18PSI (±1.25kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 580.15PSI (4000kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 10.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1PSI (±6.89kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.07PSI (0.5kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 3625.94PSI (25000kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 10.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.18PSI (1.25kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 40PSI ~ 500PSI (275.8kPa ~ 3447.4kPa), Output: SPST-NC, Voltage - Supply: ±2%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 580.15PSI (4000kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 47 mV (5), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 295 mV (5V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 110 mV (5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±2%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 150PSI (1034.21kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 1450.38PSI (10000kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±30PSI (±206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 207 mV (5V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 25 mV ~ 65 mV, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±60PSI (±413.69kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 36.26PSI (250kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 150 mV (5V), Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 145.04PSI (1000kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 14.5PSI (100kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±3.63PSI (±25kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 23.21PSI (160kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.3PSI (±2.07kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±2.32PSI (±16kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 60 mV ~ 150 mV, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 362.59PSI (2500kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,