Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 200PSI (1378.95kPa), Output: LCD Display, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 75 mV (5V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 145.04PSI (1000kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 435.1PSI (3000kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 362.59PSI (2500kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 30.5 mV (5V), Voltage - Supply: ±0.15%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 50PSI (344.74kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.75 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 232.06PSI (1600kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV (12V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 150PSI (1034.21kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 26.25 mV (5V), Voltage - Supply: ±0.15%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 5000PSI (34473.79kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.18PSI (±1.25kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 40PSI ~ 500PSI (275.8kPa ~ 3447.4kPa), Output: SPST-NC, Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.36PSI (±2.5kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 500PSI (3447.38kPa), Output: Analog Voltage, Accuracy: 1 V ~ 6 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 23.21PSI (160kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 300PSI (2068.43kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.36PSI (±2.49kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±100PSI (±689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 172.5 mV (5V), Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 87.02PSI (600kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±05%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±15PSI (±103.42kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 6000PSI (41368.54kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1PSI (6.89kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 18 mV (12V), Voltage - Supply: ±2%,