Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1PSI (6.89kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1.08PSI (7.48kPa), Output: I²C, Accuracy: 14 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.18PSI (1.25kPa), Output: I²C, Accuracy: 14 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.07PSI (0.5kPa), Output: I²C, Accuracy: 14 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.15PSI (1kPa), Output: I²C, Accuracy: 14 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: SPI, Accuracy: 14 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.15%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.07PSI (0.5kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.75 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.07PSI (0.5kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1PSI (6.89kPa), Output: I²C, Accuracy: 14 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: I²C, SPI, Accuracy: 24 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1PSI (6.89kPa), Output: I²C, SPI, Accuracy: 24 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: I²C, SPI, Accuracy: 24 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 300PSI (2068.43kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Sealed Gauge, Output Type: 3000PSI (20684.27kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 125 mV, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 50PSI (344.74kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 1000PSI (6894.76kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 125 mV, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 300PSI (2068.43kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,