Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Sealed Gauge, Output Type: 1000PSI (6894.76kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV (10V), Voltage - Supply: ±0.35%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Sealed Gauge, Output Type: 507.63PSI (3500kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 200 mV, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 101.53PSI (700kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 50PSI (344.74kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 125 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 50 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 29.01PSI (200kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 3 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 50PSI (344.74kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 50 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 50 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 50PSI (344.74kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 30PSI (206.84kPa), Output: ZACwire™, Accuracy: 14 b, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 50 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 125 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 125 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 50PSI (344.74kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 125 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.073PSI (0.5kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 3 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 300PSI (2068.43kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 29.01PSI (200kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.36PSI (2.49kPa), Output: ZACwire™, Accuracy: 14 b, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 507.63PSI (3500kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 200 mV, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 60 mV (3V), Voltage - Supply: ±0.2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 50 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 1000PSI (6894.76kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV (10V), Voltage - Supply: ±0.35%,