Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 87.02PSI (600kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.36PSI (±2.49kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 60PSI (413.69kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 725.19PSI (5000kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.36PSI (2.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 39.5 mV (5V), Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 5076.32PSI (35000kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.72PSI (±4.96kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 3000PSI (20684.27kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 87.02PSI (600kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±05%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 500PSI (3447.38kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 500PSI (3447.38kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 2.32PSI (16kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 75.5 mV (5V), Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 100PSI (689.48kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.36PSI (2.49kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 150PSI (1034.21kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 45.75 mV (5V), Voltage - Supply: ±0.15%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 150PSI (1034.21kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 110 mV (5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 150 mV (5V), Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 100PSI (689.48kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 100PSI (689.48kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 150PSI (1034.21kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.23PSI (±1.6kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 110 mV (5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.04PSI (±0.25kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.3PSI (±2.07kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 60PSI (413.69kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±30PSI (±206.84kPa), Output: I²C, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±5PSI (±34.47kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 75 mV (5V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 47 mV (5V), Voltage - Supply: ±0.25%,