Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.08PSI (7.48kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1.08PSI (±7.48kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1.08PSI (±7.48kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±30PSI (±206.84kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1.08PSI (7.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 30 mV (4.5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.08PSI (7.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1.08PSI (7.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±30PSI (±206.84kPa), Output: Wheatstone Bridge, Accuracy: 0.25 V ~ 4.75 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.15PSI (1kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 25 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.15PSI (1kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 25 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.15PSI (1kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 25 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.15PSI (1kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 25 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.15PSI (1kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 40 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.18PSI (1.25kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 22.5 mV (4.5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±5PSI (±34.47kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.18PSI (±1.25kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 60 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.18PSI (1.25kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 22.5 mV (4.5V), Voltage - Supply: ±0.5%,