Type: Position Detector, Function: 3/2 Normally Closed, Actuator Type: Round (Pin Plunger), Operating Pressure: 44 ~ 116PSI (3 ~ 8 bar), Orifice Diameter: 0.079" (2.00mm), Fluid Type: Air, Inert Gas,
Type: Solenoid Valve, Function: 3/2 Normally Closed, Operating Pressure: 15 ~ 116PSI (1 ~ 8 bar), Orifice Diameter: 0.020" (0.50mm), Fluid Type: Air, Inert Gas,
Type: Logic Element, Function: LOGIC AND, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Fluid Type: Air, Inert Gas,
Type: Control Valve, Momentary, Function: 4/2, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Fluid Type: Air, Inert Gas,
Type: Logic Element, Function: LOGIC OR, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Fluid Type: Air, Inert Gas,
Type: Timer, Fixed, Function: Positive Output, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Fluid Type: Air, Inert Gas,
Type: Impulse Generator, Adjustable, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Fluid Type: Air, Inert Gas,
Type: Control Valve, Momentary, Function: 4/2, Operating Pressure: 44 ~ 116PSI (3 ~ 8 bar), Orifice Diameter: 0.118" (3.00mm), Fluid Type: Air, Inert Gas,
Type: Control Valve, Momentary, Function: 3/2 Normally Closed, Operating Pressure: 44 ~ 116PSI (3 ~ 8 bar), Orifice Diameter: 0.118" (3.00mm), Fluid Type: Air, Inert Gas,
Type: Sub-Base, End,
Type: Control Relay, Function: One-Way, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.098" (2.50mm), Fluid Type: Air, Inert Gas,
Type: Flow Restrictor, Adjustable, Function: One-Way, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.067" (1.70mm), Fluid Type: Air, Inert Gas,
Type: Sequencer, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Fluid Type: Air, Inert Gas,
Type: Frequency Generator, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Fluid Type: Air, Inert Gas,
Type: Vacuum Switch, Function: Positive Output, Operating Pressure: -1 ~ -13PSI (-0.1 ~ -0.9 bar), Fluid Type: Air, Inert Gas,
Type: Control Valve, Momentary, Function: 3/2 Normally Open, Operating Pressure: 44 ~ 116PSI (3 ~ 8 bar), Fluid Type: Air, Inert Gas,
Type: Sub-Base, Intermediate, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Fluid Type: Air, Inert Gas,
Type: Sub-Base,
Type: Sequencer, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Fluid Type: Air, Inert Gas,
Type: Vacuum Switch, Function: Negative Output, Operating Pressure: -1 ~ -13PSI (-0.1 ~ -0.9 bar), Fluid Type: Air, Inert Gas,
Type: Vacuum Generator, Function: Pressure Operated, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Fluid Type: Air, Inert Gas,
Type: Sub-Base, End, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar),
Type: Solenoid Valve, Function: 3/2 Normally Closed, Operating Pressure: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Fluid Type: Air, Inert Gas,