Pressure Type: Board Mount,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 300PSI (2068.43kPa), Output: Analog Voltage, Accuracy: 1 V ~ 5 V, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 500PSI (3447.38kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 200PSI (1378.95kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 200PSI (1378.95kPa), Output: Analog Voltage, Accuracy: 1 V ~ 5 V, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 1500PSI (10342.14kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 3000PSI (20684.27kPa), Output: Analog Voltage, Accuracy: 1 V ~ 5 V, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5PSI (34.47kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 60PSI (413.69kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.06PSI (0.4kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1PSI (±6.89kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 15 mV (5V), Voltage - Supply: ±0.2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 47 mV (5), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 25 mV ~ 65 mV, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Sealed Gauge, Output Type: 3625.94PSI (25000kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 3.63PSI (25kPa), Output: Analog Voltage, Accuracy: 0.33 V ~ 2.97 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 150PSI (1034.21kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 5PSI (34.47kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 75 mV (5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±5PSI (±34.47kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 25.5 mV (5V), Voltage - Supply: ±0.15%,
Pressure Type: Board Mount, Operating Pressure: Vacuum, Output Type: -14.65PSI (-101kPa), Output: NPN - Open Collector,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 2.18PSI ~ 16.68PSI (15kPa ~ 115kPa), Output: Analog Voltage, Accuracy: 0.2 V ~ 4.8 V, Voltage - Supply: ±1.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 7.25PSI ~ 16.68PSI (50kPa ~ 115kPa), Output: I²C, Accuracy: 10 b, Voltage - Supply: ±0.145PSI (±1kPa),
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.51PSI (3.49kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4 V, Voltage - Supply: ±0.4%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 3625.94PSI (25000kPa), Output: Analog Voltage, Accuracy: 0 mV ~ 100 mV (10V), Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 14.5PSI (100kPa), Output: Analog Current, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.5%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 580.15PSI (4000kPa), Output: Analog Voltage, Accuracy: 0 V ~ 5 V, Voltage - Supply: ±0.25%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Analog Voltage, Accuracy: 0.5 V ~ 4.5 V, Voltage - Supply: ±0.1%,
Pressure Type: Industrial, Operating Pressure: Absolute, Output Type: 17.6PSI (121.35kPa), Output: RS-485, Voltage - Supply: ±0.06%,
Pressure Type: Industrial, Output Type: 3625.94PSI (25000kPa), Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±0.3%,
Pressure Type: Industrial, Operating Pressure: Differential, Output Type: 0.73PSI (5kPa), Output: NPN - Open Collector, Accuracy: 4 mA ~ 20 mA, Voltage - Supply: ±3%,