Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 2PSI (13.79kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.3%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 500PSI (3447.38kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 50 mV, Voltage - Supply: ±0.1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.36PSI (2.49kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1PSI (6.89kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 18 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.36PSI (2.49kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.36PSI (2.49kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1PSI (6.89kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 18 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 15PSI (103.42kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.04PSI (0.25kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.36PSI (2.49kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 100PSI (689.48kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.36PSI (2.49kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: -0.14PSI ~ 1.71PSI (-0.98kPa ~ 11.77kPa), Output: Analog Voltage, Accuracy: 0.28 V ~ 4.5 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1PSI (6.89kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 18 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.02PSI (±0.1kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±15PSI (±103.42kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 100PSI (689.48kPa), Output: Wheatstone Bridge, Accuracy: 0.25 V ~ 4.75 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 100PSI (689.48kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.04PSI (0.25kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 7 mV (4.5V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.3%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 15PSI (103.42kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.3%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.36PSI (±2.49kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 0.18PSI (1.25kPa), Output: Analog Voltage, Accuracy: 1 V ~ 7 V, Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Analog Voltage, Accuracy: 0 mV ~ 100 mV (10V), Voltage - Supply: ±0.25%,