Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 362.59PSI (2500kPa), Output: Wheatstone Bridge, Accuracy: 6 mV ~ 95 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 232.06PSI (1600kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 124.8 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 14.5PSI (100kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 120 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 23.21PSI (160kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 112 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 145.04PSI (1000kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 120 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 580.15PSI (4000kPa), Output: Wheatstone Bridge, Accuracy: 6 mV ~ 95 mV (5V),
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 362.59PSI (2500kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 120 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 23.21PSI (160kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 112 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 5.8PSI (40kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 120 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 362.59PSI (2500kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 125 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.45PSI (10kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 50 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 87.02PSI (600kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 120 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 87.02PSI (600kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 120 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 0.36PSI (2.5kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 120 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 15PSI (103.42kPa), Output: Analog Voltage, Accuracy: 0 mV ~ 79.5 mV (3V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 8.7PSI ~ 15.95PSI (60kPa ~ 110kPa), Output: Analog Voltage, Accuracy: 0 V ~ 4.25 V, Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1.08PSI (±7.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 42 mV (3.3V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 8.7PSI ~ 15.95PSI (60kPa ~ 110kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.72PSI (±4.96kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 38 mV (3.3V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 8.7PSI ~ 15.95PSI (60kPa ~ 110kPa), Output: SPI, Accuracy: 12 ~ 14 b, Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 8.7PSI ~ 15.95PSI (60kPa ~ 110kPa), Output: Wheatstone Bridge, Accuracy: 52.2 mV ~ 95.7 mV (12V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±0.04PSI (±0.25kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 8 mV (3.3V), Voltage - Supply: ±2%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 5000PSI (34473.79kPa), Output: Analog Voltage, Accuracy: 100 mV ~ 900 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Industrial, Operating Pressure: Vented Gauge, Output Type: 500PSI (3447.38kPa), Output: Analog Voltage, Accuracy: 100 mV ~ 900 mV (5V), Voltage - Supply: ±2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 4.35PSI ~ 15.95PSI (30kPa ~ 110kPa), Output: I²C, Accuracy: 16 ~ 19 b, Voltage - Supply: ±2%,