Pressure Type: Board Mount,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1.08PSI (±7.48kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0.25 V ~ 4.75 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.08PSI (7.48kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.3%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1.08PSI (±7.48kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±1%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1.08PSI (7.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 30 mV (4.5V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±1.08PSI (±7.48kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 30PSI (206.84kPa), Output: SPI, Accuracy: 12 b, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±30PSI (±206.84kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 30PSI (206.84kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 90 mV (12V), Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 30PSI (206.84kPa), Output: Analog Voltage, Accuracy: 0.25 V ~ 4.25 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Vented Gauge, Output Type: 1.08PSI (7.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1.08PSI (7.48kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 20 mV (12V), Voltage - Supply: ±0.25%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: ±30PSI (±206.84kPa), Output: Wheatstone Bridge, Accuracy: 0.25 V ~ 4.75 V, Voltage - Supply: ±0.5%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 14.5PSI (100kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 150 mV (5V), Voltage - Supply: ±0.2%,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 0.15PSI ~ 15.95PSI (1kPa ~ 110kPa), Output: SPI, Accuracy: 16 b,
Pressure Type: Board Mount, Operating Pressure: Absolute, Output Type: 203.05PSI (1400kPa), Output: SPI, Accuracy: 16 b,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 1PSI (6.89kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.2%,
Pressure Type: Board Mount, Operating Pressure: Differential, Output Type: 2PSI (13.79kPa), Output: Wheatstone Bridge, Accuracy: 0 mV ~ 100 mV, Voltage - Supply: ±0.2%,